Difference between revisions of "LogicAnalyser"
From Hackbox
(Created page with ' Using the software and hardware described [http://www.xs4all.nl/~jwasys/old/diy2.html here]. I've used these settings to debug the audio circuits of the MEK6800: * trigger …') |
(No difference)
|
Revision as of 02:17, 29 December 2010
Using the software and hardware described here.
I've used these settings to debug the audio circuits of the MEK6800:
- trigger channel: 1 (I wish I could disable triggering)
- pre trigger delay: 0
- sample size: 2000
- sample period: 2 (this is the resolution, but don't set to 1)
- granularity (read only): 1.65 us.
- zoom: length 5.28 ms
Caveats:
- while sampling, you cannot interact with the PC at all!
- so be careful with continuous mode: you get a brief change to stop after each sample period (which can be long depending on the settings)
- the sampling first waits for a trigger, i.e. a transition on the trigger channel.